ALUA options are associated with the LUNs in conjunction with TPGs

ALUA options are associated with the LUNs in conjunction with TPGs

An illustration regarding an enthusiastic EMC VNX or CLARiiON CX Selection

This output shows the Shop Number Type of field set to VMW_SATP_ALUA_CX, which is the same as the VMW_SATP_ALUA plug-in with additional code to handle certain commands specific to CLARiiON CX ALUA arrays.

The output also shows the Storage Array Form of Device Config line, wrapped for readability, which includes a number of parts:The first set of curly brackets, , has initiator membership–particular arrangement. This is exactly particular to EMC VNX in addition to CLARiiON category of arrays. In this place, a few options are noted:

navireg=on-This means that NaviAgent Registration option is enabled on this host. It registers the initiator with the VNX or CX array if it is not already registered. Note that you need to check the initiator record on the array to make sure that Failover Form is set to cuatro, which enables ALUA for this initiator. (You can find more details on this in Chapter 7.)

ipfilter=with the-This option filters the host’s IP address so that it is not visible to the storage array. (You’ll learn more about this in Chapter 7.)

This new ALUA AAS management setting options are closed within the an extra band of curly mounts, within that is other nested group of curly mounts to your TPG’s AAS arrangement. These represent the ALUA AAS government function options:

Explicit_allow=towards-This means that the host is configured to allow the SATP to exercise its explicit ALUA capability if the need arises (for example, in the event of a failed controller).

action_OnRetryErrors=away from-This option is set to off by default. This means that when and I/O on that path returns an error indicating the I/O can be retried, the path remains in an on state even after the I/O is retried indefinitely. When this option is set to on, the path eventually, after a certain timeout, is marked dead if the I/O retries still result in an error. (You’ll learn more about this in Chapter 7.)

TPG_id-This field shows the target port group ID. If the LUN is accessible via more than one target port group (typically two groups), both IDs are listed here. This example has TPG_id step step 1 and 2. Each TPG is listed within its own pair of curly brackets.

TPG_state-This field shows the AAS of the TPG. Notice that TPG_id 1 is in AO AAS, whereas TPG_id dos is in ANO AAS. Based on this configuration, I/O is sent to TPG_id 1.

More Advice from a keen EMC VNX/CLARiiON CX Variety

The first device in this example shows TPG_id step 1 being in AO beetalk login AAS, and on the second device, TPG_id 2 is also in the same state (AO AAS). This means that the devices are spread evenly over the array’s SPs. For example, TPG 1 on SPA services I/O to LUN 2, whereas TPG 2 on SPB services I/O to LUN 0. You should also notice from the Working Routes field that for LUN 2, the target portion of the pathname is T2, via vmhba2 and vmhba3, whereas it is T3 for LUN 0. (I explain in Chapter 2, “Fibre Channel Storage Connectivity,” Chapter 3, “FCoE Storage Connectivity,” and Chapter 7, “Multipathing and Failover,” how to identify which target belongs to which SP.)

Both devices are claimed by VMW_PSP_RR (round-robin). This means that the I/Os rotate on SPA ports via vmhba2 and vmhba3 for LUN 2, whereas for LUN 0, the I/Os rotate on SPB ports via the same HBAs. This design balances the load on the storage array SPs as well as the host’s initiators. (I explain this in Chapter 7.)